GN30-12 Indoor Rota High-voltage Isolation Switch

    GN30-12 Indoor Rota High-voltage Isolation Switch

  • Category:
    Indoor High Voltage Isolation Switch
  • Browse number:
    13
  • Release time:
    2025-03-13 10:31:07
  • Share:
  • INQUIRY

The GN30-12 rota indoor high-voltage isolation switch is a new type of isolation switch with a rotating contact blade. e main structure is to x two sets of Insulators and contacts on the upper and lower planes of the three-phase common chassis, and to achieve the opening and closing of the switch by rotating the contact blade.

The GN30-12D switch is an additional form with a grounding knife based on the GN30-12 switch, which can meet the needs of dierent power systems. is product has a compact design, small footprint, strong Insulation capacity, and is easy to install and adjust. Its peormance meets the requirements of GB1985-89 "AC High Voltage Isolation Switches and Grounding Switches" and is suitable for indoor systems with a rated voltage of 10 kVAC 50Hz and belowAs a switching circuit used in situations with voltage and no load, it can be used in conjunction with high-voltage switchgear or used independently.


1.Model and meaning


2.Environmental conditions for use

◆Altitude: not exceeding 1000m;

◆Air temperature: upper limit+40 ° C, lower limit -10 ° C;

◆Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;

◆Eahquake intensity: not exceeding magnitude 8;

◆ Pollution level: places without serious dust, chemical corrosiveness, and explosive substances;◆Installation location: A place without frequent and severe vibrations.


3.Main technical parameters


Product Model
Specification
Project/Parameters
GN30-12/400-12.5GN30-12/630-20GN30-12/1000-31.5GN30-12/1250-31.5
GN30-12D/400-12.5GN30-12D/630-20GN30-12D/1000-31.5GN30-12D/1250-31.5
Rated voltage (KV)
Rated current (A)400 630 1000 1250 
mermal stability current (KA)12.5 20 31.5 
mermal stability time (S)
Dynamic Stable Induced Abo比ion (KA)31.5 50 80 
Rated insulation level lightning
impulse voltage (KV)
Phase to phase, phase to ground 75, fracture 85
Rated insulation level 1-minute power
frequency withstand voltage (KV)
Phase to phase, phase to ground 42, fracture 48


4.Appearance and installation dimensions (mm)

GN30-12GN30-12D
400/630A1000A1250A400/630A1000A1250A
ACACACABCABCABC
560 315 580 332 580 295 550 610 240 575 615 245 580 600 295 



Comment

(0)
*Captcha:

ONLINE MESSAGE

*Subject:
*E-mail:
Phone:
Company:
*Captcha:

RELATED PRODUCTS

Youkai Electric Co., Ltd

Tel:    +86 13588970775

E-mail: 954518655@qq.com

Fax:  +86 0577-62770775

Add: 281 Central Avenue, Yueqing Economic Development Zone, 

Yueqing City, Wenzhou City,Zhejiang Province,China




Copyright ©  2023 Youkai Electric Co., Ltd  All rights reserved  

This website uses cookies to ensure you get the best experience on our website.

Accept Reject